Description
Cerabar M PMC51 Pressure Transmitter | Endress + Hauser
Product name : Pressure Transmitter
Model : Cerabar M PMC51
Part Number : GR290A1PGJGMJA
Brand : Endress + Hauser
Origin: Germany
Cerabar M PMC51 Pressure Transmitter with capacitive, oil-free ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases,,more. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.
Benefits of Cerabar M PMC51 Pressure Transmitter:
• Very good reproducibility and long-term stability
• High reference accuracy up to ±0.10 % as PLATINUM version: ±0.075 %
• Turn down up to 100:1
• Uniform platform for differential pressure, hydrostatics and pressure (Deltabar M – Deltapilot M – Cerabar M)
• Practical user navigation for quick and easy commissioning
• Used for process pressure monitoring up to SIL 2, certified to IEC 61508 Edition 2.0 and IEC 61511 by TÜV NORD
• The patented TempC process membrane for the diaphragm seal reduces the measurement error caused by environmental and process temperature effects to a minimum
• ASME BPE-compliant device versions
Application of Cerabar M PMC51 Pressure Transmitter:
The device is used for the following measuring tasks:
• Absolute pressure and gauge pressure measurement in gases, steams or liquids in all areas of process engineering and process measurement technology
• Level, volume or mass measurement in liquids
• High process temperature
• without diaphragm seals up to 130 °C (266 °F), for a maximum of 60 minutes 150 °C (302 °F)
• with diaphragm seals up to 400 °C (752 °F)
• High pressure up to 400 bar (6000 psi)
• International usage thanks to a wide range of approvals
Specification of Cerabar M PMC51 Pressure Transmitter :
Measuring principle
Absolute and gauge pressure
Characteristic
Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)
Supply voltage
4…20 mA HART
11,5…45V DC (Non Ex):
Ex ia: 11,5…30V DC
PROFIBUS PA:
9…32 V DC (Non Ex)
FOUNDATION Fieldbus:
9…32 V DC (Non Ex)Reference Accuracy
Standard 0.1%
Platinum 0.075%Long term stability
0.2% of URL/ year
0.4% of URL/ 5 years
0.5% of URL/ 10 yearsProcess temperature
-40°C…+130°C
(-40°F…+266°F
+150°C for 1h
(+302°F for 1h)Ambient temperature
-40°C…+85°C
(-40°F…+185°F)Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
relative/ absoluteSmallest calibratable span
10 mbar (0.15 psi)
Vacuum resistance
0 mbar abs.
Max. Turn down
20:1
Max. overpressure limit
60 bar (900 psi)
Process connection
Thread:
G1/2…G2, R1/2, MNPT1/2
Flange:
DN25…DN80,
ASME 1″…4″,
JIS 10KProcess connection hygienic
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRDMaterial process membrane
Ceramic
Material gasket
Viton, EPDM, NBR, Kalrez
Fill fluid
None, dry measuring cell
Material housing
Die-cast aluminum,
AISI 316LCommunication
4…20 mA
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-LinkCertificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals
SIL
Design approvals
EN10204-3.1
NACE MR0175Hygienic approvals
CoC ASME-BPE
3A, EHEDGMarine approvals
GL/ ABS/ LR/ BV/ DNV
Drinking water approvals
NSF
For complete datasheet: TSP Controls – Cerabar M PMC51 Datasheet